Recommended Alternative — The combination of the Wireless pH, Wireless Temperature, Wireless Pressure and Wireless Voltage sensors can perform all of the functions of the PASPORT Chemistry Sensor. Best of all, they connect directly* to your computers, tablets, smartphones and Chromebooks without the need for an interface and with no cables to get in the way.

*Devices without native Bluetooth® Smart connectivity will require a low cost USB adapter - see the product pages for details.

PS2170_MAIN.jpg

Overview

Gas laws, acid/base, thermochemistry and redox all with one sensor! Measure temperature, pH, absolute gas pressure and voltage. Easy to store, easy to use. All measurements can be made simultaneously. Also supports ISE and ORP electrodes (optional).

Typical Applications

  • Explore Gas Laws
  • Perform Acid/Base Investigations
  • Study Endothermic and Exothermic Reactions
  • Determine an Electrochemical Series

Includes

  • Stainless Steel Temperature Probe
  • pH Probe
  • Voltage Probe
  • Polyurethane Tubing (60 cm long)
  • Quick-release Connectors (4)
  • Tubing Connectors (4)
  • 60 cc Syringe
  • Specifications

    General

    Component Sensor
    • Temperature, pH/ISE/ORP probe voltage, Absolute Pressure, Voltage
    Default Sample Rate
    • 10 Hz
    Maximum Sample Rate
    • 100 Hz

    Temperature

    Range
    • –35 °C to +135 °C
    Accuracy
    • ±0.5 °C
    Resolution
    • 0.01 °C
    Sensing Element
    • 10 KOhm thermistor located in the probe

    pH/ISE/ORP Probe Voltage

    Electrode Connector
    • standard BNC
    Voltage Range
    • ±2000 mV
    Voltage Resolution
    • 0.1 mV
    pH Range
    • 0 to 14 pH
    pH Resolution
    • 0.001 pH

    Absolute Pressure

    Range
    • 0kPa to 700 kPa
    Accuracy
    • 2 kPa
    Resolution
    • 0.1 kPa
    Repeatability
    • 1 kPa

    Voltage

    Range
    • ±10 V
    Accuracy
    • ±0.1 V
    Resolution
    • ±0.04 mV
    Voltage Protection
    • up to 240 V
    Input Resistance
    • 2 MOhm

    Buying Guide

    Expand Your Set

    Supports the use of Ion Selective and Oxidation Reduction Potential Electrodes

    54418
    CI-6717
    Ammonium Ion Selective Electrode
    1
    54420
    CI-6726
    Carbon Dioxide Ion Selective Electrode
    1
    50673
    CI-6727
    Calcium Ion Selective Electrode
    1
    50771
    CI-6728
    Fluoride Ion Selective Electrode
    1
    50731
    CI-6732
    Chloride Ion Selective Electrode
    1
    50782
    CI-6733
    Potassium Ion Selective Electrode
    1
    50783
    CI-6734
    Sodium Ion Selective Electrode
    1
    50777
    CI-6735
    Nitrate Ion Selective Electrode
    1
    50759
    CI-6736
    Lead Ion Selective Electrode
    1
    Accessories
    Ammonium Ion Selective Electrode   CI-6717
    Carbon Dioxide Ion Selective Electrode   CI-6726
    Calcium Ion Selective Electrode   CI-6727
    Fluoride Ion Selective Electrode   CI-6728
    Chloride Ion Selective Electrode   CI-6732
    Potassium Ion Selective Electrode   CI-6733
    Sodium Ion Selective Electrode   CI-6734
    Nitrate Ion Selective Electrode   CI-6735
    Lead Ion Selective Electrode   CI-6736
    62167
    PS-2573
    pH Electrode
    1
    55765
    PS-2165
    PASPORT Voltage Probe
    1
    54399
    PS-2153
    PASPORT Stainless Steel Temperature Probe
    1
    2784461
    SC-3507
    pH Storage Solution
    Replacement Parts
    pH Electrode   PS-2573
    PASPORT Voltage Probe   PS-2165
    PASPORT Stainless Steel Temperature Probe   PS-2153
    pH Storage Solution   SC-3507

    Interface Required

    To use this product you need a PASCO interface. 

    New to probeware or have questions about  sensors or interfaces? Contact Teacher and Technical Support.  We're here to help!

    Software Required

    This product requires or recommends PASCO software for data collection and analysis. Either SPARKvue software or PASCO Capstone software may be used.