Move the switch at the top of the Motion Sensor to the Cart icon.
Connect the GLX to the Force Sensor.
Place the Force Sensor horizontally on the lab table and press the ZERO button.
Thread a 20 cm long string through the slot of one Friction Tray. Tie the ends together to make a loop. Repeat for the other trays.
SOFTWARE SETUP:
Follow the instructions below or download "frictionGLX.zip" (4 KB). Unzip the file and download the GLX file "friction.glx" to your GLX via DataStudio.
Press the Home button to get to the Home screen.
Press or navigate to the Sensors Icon.
Use the arrows to select the Motion Sensor.
Change the Sample Rate to 50 as in the picture above.
Make Position "Not Visible" and Velocity "Visible."
Use the arrows to select the Force Sensor.
Change the Sample Rate to 1000.
Make push positive "Not Visible" and pull positive "Visible."