Experimental Setup for the 500 Interface using DataStudio:
- Connect the 500 Interface to the serial port of the computer.
- Plug the Force Sensor into analog channel A.
- Incline the dynamics track at an angle of 5-10 degrees.
Attach the Force Accessory Bracket in the downhill end (see
photo below).
- Attach the Force Sensor to the PAScar or Dynamics Cart
and screw the heavy spring attachment (from the Force Accessory
Bracket) into the sensor.
Note: PASPORT sensors are used for experiment setup purposes
only and are not compatible with the 500 Interface.
To download the Collisions DataStudio file, click on a Windows
(Zip file) or Macintosh
(Stuffit file).
You are now ready to begin collecting data.
|