Experimental Setup for the 500 Interface using DataStudio:
- Connect the 500 Interface to the serial port of the computer
and plug the 1st Force Sensor into the analog channel A.
Then, plug the 2nd Force Sensor into analog channel B.
- If the Force Sensor does not have the hook installed on
the end, then install the hook. Tie a 30 cm piece of string
between the hook of the Force Sensor and the cork friction
tray (see photo below).
Note: PASPORT sensors are shown for equipment configuration
purposes only; they cannot be used with a 500 interface.
- With no force applied to the sensor, push the zero (tare)
button on the sensor. You only need to do this once!
To download the Slip Sliding Away DataStudio file, click
on a Windows (Zip
file) or Macintosh
(Stuffit file).
You are now ready to begin collecting data.
|